We are excited to announce the new actiCHamp Plus, offering a scalable and flexible solution for your laboratory EEG recordings. The actiCHamp Plus can be combined with all our active as well as passive electrode systems – incl. the R-Net, and is powered by a sturdy lithium-ion battery, the PowerUnit.
actiCHamp Plus at a glance
All electrode options to best fit your needs
Scalable solution
Highly integrated for multimodal recordings
Powered by lithium-ion technology
Available options
actiCHamp series | Technical specifications |
---|---|
Amplifier | |
Maximum number of channels | 160 EEG + 8 AUX |
Max. sampling rates for each channel combination: | |
160 channels + 8 AUX | 25 kHz |
128 channels + 8 AUX | 25 kHz |
96 channels + 8 AUX | 25 kHz |
64 channels + 8 AUX | 50 kHz |
32 channels + 8 AUX | 100 kHz |
Maximum bandwidth of the EEG channels | DC up to 7,500 Hz |
Digitization | 24-bit, one converter/channel |
Battery (PowerUnit) | |
Max. number of amplifiers | 1 |
Rechargeable battery type | Lithium-ion (lithium iron phosphate (LiFe-PO4)) |
Operating time for one amplifier | Max. 16 hours (with a fully charged, new battery) |
Charging time | Typically 12 hours with FRIWO charger (at room temperature with empty battery) Typically 5 hours with Mascott charger (at room temperature with empty battery) |
actiCHamp series | Technical specifications |
---|---|
Amplifier | |
Resolution | EEG channels: 0.819.2 V⁄(2^24 Bit)≈0.04883 μV/Bit AUX channels: As of Rev. 02: 10 V/(2^24 Bit)≈0.596 μV/Bit |
Integrated AUX/bipolar channels (base module) | Yes, 8 AUX channels |
Input voltage range | ±400 mV (EEG), ±4.8 V (AUX) |
Input noise | 2 μVpp (DC – 35 Hz) |
Input impedance (for DC) | EEG channels: > 1,000 MΩ AUX channels: As of Rev. 01: 40 MΩ |
Use with active electrodes | Yes |
Use with passive electrodes | Yes |
Impedance measurement | Yes, three colors, displayed via LEDs for active electrodes |
Common-mode rejection (CMR) | 100 dB (according to IEC 60601-2-26) |
Trigger input | 8 bit TTL (LVTTL) signals, 0 to +5 V (+ 3.3 V), max. 10 mA |
Trigger output | 8 bit TTL signals, 0 to +5 V, max. 10 mA |
Synchronization output | 3.5 mm stereo jack TTL signal, always ON Clock signal of A/D converter, based on the three basic sampling rates of the amplifier (10 kHz, 50 kHz, 100 kHz) |
Dimensions (H x W x D) | Approx. 68 mm x 160 mm x 187 mm |
Weight | Approx. 1.1 kg |
Battery (PowerUnit) | |
Rated voltage | 6.6 V DC |
Rated capacity | 12.5 Ah |
Rated energy | 82.5 Wh |
Output current | Max. 3 A |
Dimensions (H x W x D) | Approx. 68 mm x 160 mm x 187 mm |
Weight | Approx. 1.2 kg |
State of charge (SOC) for transport | < 30% of full capacity |
State of charge (SOC) for storage | 30% up to 80% of full capacity For longer storage periods: Start with 80% SOC for extending the time period until SOC falls short of 30% by self-discharge |
Miscellaneous | |
Suitable for use in MR scanner room | No |
Medical device | No |
CE marking | The Brain Products GmbH confirms the electromagnetic compatibility (EMC) of this product according to the Directive 2014/30/ EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to electromagnetic compatibility. The Brain Products GmbH confirms the RoHS compliance of this product according to Directive 2011/65/EU of the European Parliament and the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment (recast published in the Official Journal of the European Union on 1 July 2011) as well as all its amendments up to and including the Commission delegated directive (EU) 2015/863 of 31 March2015 (published in the 0fficial Journal of the European Union on 4 June 2015). |
EMC-tested in accordance with EN 61326-1:2013 (IEC 61326-1:2012) | Yes |
For more information or to speak with the
Brain Vision Scientific Consulting Team dial
(877) EEG-4MRI or schedule a call
Billing address:
Brain Vision, LLC
1204 Village Market PL #300
Morrisville, NC 27560
Shipping address:
Brain Vision, LLC
515 N. Greenfield Parkway, Suite 100
Garner, NC 27529
Cookie | Duration | Description |
---|---|---|
cookielawinfo-checkbox-analytics | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Analytics". |
cookielawinfo-checkbox-functional | 11 months | The cookie is set by GDPR cookie consent to record the user consent for the cookies in the category "Functional". |
cookielawinfo-checkbox-necessary | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookies is used to store the user consent for the cookies in the category "Necessary". |
cookielawinfo-checkbox-others | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Other. |
cookielawinfo-checkbox-performance | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Performance". |
viewed_cookie_policy | 11 months | The cookie is set by the GDPR Cookie Consent plugin and is used to store whether or not user has consented to the use of cookies. It does not store any personal data. |
* indicates required fields
Please select your area to schedule an introductory call with one of our Scientific Consultants.
script here