Transcranial Focal Stimulator

The Transcranial Focal Stimulator is designed to be compatible with our unique concentric ring electrodes. It is a constant current stimulator. The user can configure the stimulator through an efficient user interface consisting of a character LCD and a five-button pad. There are five indicator LEDs: device on, stimulation active, over current detected, out of range impedance, and low battery.

The user can set stimulation parameters: current amplitude, pulse duration, frequency, and train duration.

In addition to pulse trains, four arbitrary waveforms are available to the user.

The stimulator runs off 4-AA batteries, has built-in impedance checking, and can provide up to 100 mA (into a 2kΩ load), with pulses from 50 µs to 500 µs, at frequencies from zero to 500 Hz.

Related Products

The LOOP-IT's front panel is depicted with its touchscreen interface, 8x EEG inputs, 2x tES outputs, 4x BNC outputs, and a special port.
The neuroConn LOOP-IT is an all-in-one solution for closed loop EEG-tES, TMS-EEG, and EEG-tFUS.

neuroConn LOOP-IT

neuroConn DCMC is pictured with its control panel PC, keyboard, and mouse, along with 4x stimulation channels connected to a glass head via rubber electrodes.
An expandalbe multi-channel transcranial electrical stimulation (HD-tES) platform.

neuroConn DC-STIMULATOR MC

neuroConn DC-STIMULATOR PLUS is depicted laying on a table with a pair of rubber/sponge electrodes connected.
A capable and powerful one-channel transcranial electrical stimulation (tES) tool.

neuroConn DC-STIMULATOR PLUS

The BESA Connectivity software interface is a workflow-based GUI that walks you through the connectivity analysis of your choosing. Here you see the results of a Coherence analysis between multiple regional sources (source space, frequency anlaysis).
BESA Connectivity is a stand-alone module that extends BESA Research with streamlined, user-guided workflows for time–frequency and connectivity analysis of EEG and MEG data (in both scalp and source space). With multiple time–frequency and connectivity analysis methods supported, you can run batch analyses across subjects and easily visualize results using a variety of 2D and 3D renderings. The output is also ready for direct import into BESA Statistics.

BESA Connectivity 2.0

View Other Application Fields

Website Search

Schedule a call with our Consultants​

Please select your area to schedule an introductory call with one of our Scientific Consultants.

script here