Cap with actiCAP SNAP holders (for actiCAP Slim electrodes)

Cap with actiCAP SNAP holders (for actiCAP Slim electrodes)

This cap is equipped with actiCAP SNAP holders for the actiCAP slim electrodes, for use with the actiCAP /
actiCHamp system. Caps include the respective number of actiCAP SNAP holders including a holder for GND and REF (REF will
not be needed for use with actiCHamp).

Corresponding to the bundles of 32 actiCAP active electrodes, the holders in the caps are color-coded in groups of 32. Each group is number-labeled 1-32.  ALL Caps listed here use the layout as named in the layout document, and come with integrated chin belt and buckles to attach a chest belt.

TO BE SPECIFIED SIZES are given in cm head circumference. Please replace the wildcard # by the intended size.

  • Average adult male size is 58, average adult female size is 56. Newborn size is 36.
  • Cap sizes 64 to 52 come with high precision cap fabric, smaller sizes 50 to 32 with softer, high-elasticity fabric.
  • ASIA CUT can be specified at no charge.
  • 21 Channels is possible for all sizes
  • 32 Channels is possible for size 36 and larger
  • 64 Channels is possible for size 42 and larger
  • 96 / 128 / 160 Channels are possible for size 52 and larger

Related Products

The LOOP-IT's front panel is depicted with its touchscreen interface, 8x EEG inputs, 2x tES outputs, 4x BNC outputs, and a special port.
The neuroConn LOOP-IT is an all-in-one solution for closed loop EEG-tES, TMS-EEG, and EEG-tFUS.

neuroConn LOOP-IT

neuroConn DCMC is pictured with its control panel PC, keyboard, and mouse, along with 4x stimulation channels connected to a glass head via rubber electrodes.
An expandalbe multi-channel transcranial electrical stimulation (HD-tES) platform.

neuroConn DC-STIMULATOR MC

neuroConn DC-STIMULATOR PLUS is depicted laying on a table with a pair of rubber/sponge electrodes connected.
A capable and powerful one-channel transcranial electrical stimulation (tES) tool.

neuroConn DC-STIMULATOR PLUS

The BESA Connectivity software interface is a workflow-based GUI that walks you through the connectivity analysis of your choosing. Here you see the results of a Coherence analysis between multiple regional sources (source space, frequency anlaysis).
BESA Connectivity is a stand-alone module that extends BESA Research with streamlined, user-guided workflows for time–frequency and connectivity analysis of EEG and MEG data (in both scalp and source space). With multiple time–frequency and connectivity analysis methods supported, you can run batch analyses across subjects and easily visualize results using a variety of 2D and 3D renderings. The output is also ready for direct import into BESA Statistics.

BESA Connectivity 2.0

View Other Application Fields

Website Search

Schedule a call with our Consultants​

Please select your area to schedule an introductory call with one of our Scientific Consultants.

script here